Importing from grid by 0.437 kW
12/14/2025 15:40 (2027 days) Production Consumption NET Usage
Now 0.206 kW 0.643 kW 0.437 kW
Today 0.227 kWh (0.014 kW) 9.200 kWh (0.586 kW) 8.973 kWh (0.571 kW)
  - This Week 0.227 kWh (0.347 kWh/day) 9.200 kWh (14.055 kWh/day) 8.973 kWh (13.708 kWh/day)
  - This Month 120.978 kWh (8.860 kWh/day) 270.473 kWh (19.809 kWh/day) 149.495 kWh (10.949 kWh/day)
  - This Year 5.990 MWh (17.230 kWh/day) 7.187 MWh (20.672 kWh/day) 1.197 MWh (3.443 kWh/day)
Yesterday 4.770 kWh (0.199 kW) 60.063 kWh (2.503 kW) 55.293 kWh (2.304 kW)
Last 7 Days 67.929 kWh (9.705 kWh/day) 171.740 kWh (24.537 kWh/day) 103.811 kWh (14.832 kWh/day)
Last 30 Days 275.456 kWh (9.182 kWh/day) 585.601 kWh (19.521 kWh/day) 310.145 kWh (10.339 kWh/day)
Last One Year 6.115 MWh (16.753 kWh/day) 7.575 MWh (20.755 kWh/day) 1.461 MWh (4.002 kWh/day)
Lifetime Since PTO 35.441 MWh (17.478 kW/day) 39.140 MWh (19.302 kW/day) 3.699 MWh (1.824 kW/day)
Lifetime Since Install 35.475 MWh 39.720 MWh 4.245 MWh
Voltage/Current 250.0 V / 0.8 A 250.0 V / 2.6 A 250.0 V / 1.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/17/2022 22:09 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.677 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.035 0.882 11.128 0.000 kW
1.992 kWh
0.000 kW
11.949 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.969 0.819 10.481
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.054 0.864 10.749
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.997 0.868 10.661
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.929 0.848 9.990
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.966 0.856 10.639
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.916 0.788 10.053 0.000 kW
1.885 kWh
0.000 kW
9.423 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.820 0.793 9.740
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.839 0.770 9.847
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.906 0.772 10.077
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.943 0.800 10.184
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.281 1.853 0.858 11.013 0.000 kW
1.826 kWh
0.000 kW
7.305 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.277 1.768 0.864 10.706
14 - 202216****** IQ7+ [5] VCOP 0.000 0.281 1.858 0.879 11.134
15 - 202245****** IQ7+M [0] V--- 0.000 0.277 1.826 0.870 10.969
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.46 V Current/Power -5.88 A (-0.308 kW)
Remain Capacity/Energy 288.3 Ah (14.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 48.1 % State Of Health 100.0 %
Run Time 2d 1h 1m to empty Report Date 2022-06-17 23:57