Date Offset  [+30][+10][+05][+01][-01][-05][-10]

Exporting to grid by 4.040 kW
06/17/2026 13:12 (2212 days) Production Consumption NET Usage
Now 4.217 kW 0.177 kW -4.040 kW
Today 15.144 kWh (1.147 kW) 2.450 kWh (0.186 kW) -12.694 kWh (-0.962 kW)
  - This Week 107.657 kWh (30.325 kWh/day) 40.780 kWh (11.487 kWh/day) -66.877 kWh (-18.838 kWh/day)
  - This Month 566.009 kWh (34.197 kWh/day) 423.661 kWh (25.597 kWh/day) -142.348 kWh (-8.600 kWh/day)
  - This Year 3.300 MWh (19.698 kWh/day) 2.994 MWh (17.867 kWh/day) -0.307 MWh (-1.831 kWh/day)
Yesterday 34.173 kWh (1.423 kW) 1.725 kWh (0.072 kW) -32.448 kWh (-1.352 kW)
Last 7 Days 205.865 kWh (29.409 kWh/day) 199.365 kWh (28.481 kWh/day) -6.500 kWh (-0.929 kWh/day)
Last 30 Days (05/18/2026) 899.305 kWh (29.977 kWh/day) 700.067 kWh (23.336 kWh/day) -199.238 kWh (-6.641 kWh/day)
Last One Year 6.689 MWh (18.327 kWh/day) 7.866 MWh (21.551 kWh/day) 1.177 MWh (3.224 kWh/day)
Lifetime Since PTO 38.866 MWh (17.566 kW/day) 42.504 MWh (19.211 kW/day) 3.638 MWh (1.644 kW/day)
Lifetime Since Install 38.900 MWh 43.084 MWh 4.184 MWh
Voltage/Current 251.3 V / 16.8 A 251.4 V / 0.7 A 251.3 V / -16.1 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 06/07/2026 23:56 (23.9 hours) Number of Devices 17 set
Current Power 0.321 kW (0.019 kW/panel) Today Energy 38.411 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.120 1.677 15.006 0.000 kW
1.988 kWh
0.000 kW
11.926 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.969 1.563 13.929
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.991 1.595 14.132
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.021 1.607 14.367
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.774 1.479 12.640
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.050 1.619 14.452
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.879 1.525 13.220 0.000 kW
1.881 kWh
0.000 kW
9.407 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.813 1.555 13.122
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.865 1.556 13.265
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.908 1.556 13.419
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.942 1.569 13.679
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.281 2.104 1.663 14.883 0.000 kW
2.122 kWh
0.000 kW
8.486 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 2.076 1.679 14.807
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 2.152 1.729 15.280
15 - 202245****** IQ7+M [5] VCOP 0.000 0.287 2.154 1.739 15.299
wind 16 - 202320****** IQ7XS [5] VCOP 0.321 0.322 7.676 7.671 42.980 0.161 kW
4.296 kWh
0.321 kW
8.592 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.168 0.916 0.730 6.448
Panel Layout Each Group Production

Charger History
Voltage PV 0.27 V Voltage Charge 52.36 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.6 °C / 27.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-06-07 23:59
voltage in/out power and energy

Battery History
Voltage 52.65 V Current/Power -7.93 A (-0.417 kW)
Remain Capacity/Energy 315.9 Ah (16.2 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 57.6 % State Of Health 91.4 %
Run Time 1d 15h 50m to empty Report Date 2026-06-07 23:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.